SICK FRANCE
STR1
Small, safe and flexible The STR1 transponder safety switch has monitored semiconductor outputs (OSSDs) and can be wired individually or in series. It is used in applications requiring high protection against manipulation. The STR1 is available with three codings. Universally coded sensors are compatible with all actuators. For the uniquely coded and permanently coded versions, an actuator must be programmed. Then, the STR1 only accepts this actuator. The sensor has three active detection surfaces. There are three different major actuators. The STR1 thus offers great mounting flexibility.
Monitoring of protective doors and removable protective devices Applications requiring a high standard of hygiene Applications where precise guidance of the protective door is not possible Machines and installations on which vibrations occur Position monitoring of transfer trolleysTriggering area up to 14 mm Small housing offers flexible mounting possibilities Sensor activation possible from three sides Three different actuators available Universally coded, uniquely coded and permanently coded sensors PL e (EN ISO 13849), SIL3 (IEC 61508) Safe series connection possible up to 30 sensors